ASTM Thermometers Page 2
(Page 2)
| Cat. No. |
Test |
ASTM No. |
Scale Range° |
Div.° |
Len. mm. |
lmm. mm. |
| 405A293 |
Engler Viscosity |
23C |
18 to 28 C |
.2C |
212 |
90 |
| 405A294 |
Engler Viscosity |
24C |
39 to 54 C |
.2C |
237 |
90 |
| 405A295 |
Engler Viscosity |
25C |
95 to 105 C |
.2C |
212 |
90 |
| 405A296 |
Stability Test of Nitrocellulose |
26C |
130 to 140 C |
.1C |
463 |
Total |
| 405A297 |
Turpentine Distillation |
27C |
147 to 182 C |
.5C |
301 |
76 |
| 405A298 |
Kinematic Viscosity |
28F |
97.5 to 102.5 F |
.1F |
305 |
Total |
| 405A299 |
Kinematic Viscosity |
29F |
127.5 to 132.5 F |
.1F |
305 |
Total |
| 405A300 |
Kinematic Viscosity |
30F |
207.5 to 212.5 F |
.1F |
305 |
Total |
| 405A301 |
Reid Vapor Pressure Air Chamber |
31F |
-30 to 120 F |
.1F |
305 |
Total |
| 405A302 |
Aniline Point |
33C |
-38 to 42 C |
.2C |
419 |
50 |
| 405A303 |
Aniline Point |
33F |
-36.5 to 107.5 F |
.5F |
419 |
50 |
| 405A304 |
Aniline Point |
34C |
25 to 105 C |
.2C |
419 |
50 |
| 405A305 |
Aniline Point |
34F |
77 to 221 F |
.5F |
419 |
50 |
| 405A306 |
Aniline Point |
35C |
90 to 170 C |
.2C |
419 |
50 |
| 405A307 |
Aniline Point |
35F |
194 to 338 F |
.5F |
419 |
50 |
| 405A308 |
Titer Test |
36C |
-2 to 68 C |
.2C |
405 |
45 |
| 405A309 |
Solvents Distillation |
37C |
-2 to 52 C |
.2C |
395 |
100 |
| 405A310 |
Solvents Distillation |
38C |
24 to 78 C |
.2C |
395 |
100 |
| 405A311 |
Solvents Distillation |
39C |
48 to 102 C |
.2C |
395 |
100 |
| 405A312 |
Solvents Distillation |
40C |
72 to 126 C |
.2C |
395 |
100 |
| 405A313 |
Solvents Distillation |
41C |
98 to 152 C |
.2C |
395 |
100 |
| 405A314 |
Solvents Distillation |
42C |
95 to 255 C |
.5C |
395 |
100 |
| 405A315 |
Kinematic Viscosity |
43F |
-61 to -29 F |
.2F |
420 |
Total |
| 405A316 |
Kinematic Viscosity |
44C |
18.6 to 21.4 C |
.05C |
305 |
Total |
| 405A317 |
Kinematic Viscosity |
44F |
66.5 to 71.5 F |
.1F |
305 |
Total |
| 405A318 |
Kinematic Viscosity |
45C |
23.6 to 26.4 C |
.05C |
305 |
Total |
| 405A319 |
Kinematic Viscosity |
45F |
74.5 to 79.5 F |
.1F |
305 |
Total |
| 405A320 |
Kinematic Viscosity |
46C |
48.6 to 51.4 C |
.05C |
305 |
Total |
| 405A321 |
Kinematic Viscosity |
46F |
119.5 to 124.5 F |
.1F |
305 |
Total |
| 405A322 |
Kinematic Viscosity |
47C |
58.6 to 61.4 C |
.05C |
305 |
Total |
| 405A323 |
Kinematic Viscosity |
47F |
137.5 to 142.5 F |
.1F |
305 |
Total |
| 405A324 |
Kinematic Viscosity |
48F |
177.5 to 182.5 F |
.1F |
305 |
Total |
| 405A325 |
Stormer Viscosity |
49C |
20 to 70 C |
.2C |
305 |
65 |
| 405A326 |
Gas Calorimeter Inlet |
50F |
54 to 101 F |
.1F |
468 |
Total |
| 405A327 |
Gas Calorimeter Outlet |
51F |
69 to 116 F |
.1F |
468 |
Total |
| 405A328 |
Gas Calorimeter Flue |
52F |
54 to 101 F |
.1F |
209 |
Total |
| 405A329 |
Butadiene Boiling Point Range |
52C |
-10 to 5 C |
.1C |
162 |
Total |
| 405A330 |
Benzene Freezing Point |
53C |
-0.6 to 10.4 C |
.1C |
189 |
Total |
| 405A331 |
Congealing Point |
54C |
20 to 100 C |
.2C |
312 |
Total |
| 405A332 |
Congealing Point |
54F |
68 to 213 F |
.5F |
312 |
Total |
| 405A333 |
Bomb Calorimeter |
56C |
19 to 35 C |
.02C |
585 |
Total |
| 405A334 |
Bomb Calorimeter |
56F |
66 to 95 F |
.05F |
585 |
Total |
| 405A335 |
Tag Closed Tester Low Range |
57C |
-20 to 50 C |
.5C |
287 |
57 |
| 405A336 |
Tag Closed Tester Low Range |
57F |
-4 to 122 F |
1F |
287 |
57 |
If you are interested in purchasing these products or would like additional information about these products call 1-800-421-8329 or fill out the form below and click Submit.
Glass Thermometers | ASTM Thermometer 1 | ASTM Thermometer 2 | ASTM Thermometer 3 | ASTM Thermometer 4
|
|
|
Call to order any of the products you find on this website.


If you want the best certification of hydrometers, centrifuge tubes and thermometers for the best cost, you need to give us a call today !! We will match or beat any other qualified laboratory certification cost !
You will be pleased with the considerable dollar savings for you and your company.
|
|